DKK-TOA MM-60R
|
|
2-Channel model with automatic sensor identification
Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel
0.01/0.001 pH display switchable
Large color graphic LCD display
JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement
USB (Host) and LAN equipped as standard specification
External printer connectable
Multiple sample measuring capability (turntable connection)
Data storage up to 300... |
Dissolved Oxygen Meter
|
|
|
DKK-TOA U-221
|
|
Alternative model to existing controller such as U-22, U-02, etc.
Same panel cut size, easy installation
Interactive input interface supports auto-calibration and multi-stream
Auto-calibration, self-diagnostic, remote control, communication function equipped
|
Controller
|
|
|
DKK-TOA U-32 / U-42(Explosion proof type)
|
|
Controller (For Oil Refineries) U-32 / U-42(Explosion proof type)
Intelligent controller best suited for use with FPA, PPA and CPA
Applicable to multi-stream system, interactive data entry via display & automatic calibration
Auto-calibration, self-diagnostic, remote control, communication function equipped
|
Controller
|
|
|
DKK-TOA CM-30R
|
|
JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement
Built-in pure water temperature compensation
USB (Host) and LAN equipped as standard specification
Compliant with USP<645> requirements
Meas. range
0 - 200.0 S/m 0 - 20.00 MΩ・m Chloride 0 - 4.00% Concentration 0 - 200% 0 - 100.0 degrees C |
Conductivity Meter
|
|
|
DKK-TOA CM-25R
|
|
Low-cost basic model
Easy-to-read large customized LCD display
External printer connectable
Data storage up to 300 points
Compliant with USP<645> requirements
Meas. range
0 - 200.0 S/m 0 - 20.00 MΩ・m Chloride 0 - 4.00% 0 - 100.0 degrees C |
Conductivity Meter
|
|
|
DKK-TOA MM-60R
|
|
Multi-Function Water Quality Meter MM-60R
2-Channel model with automatic sensor identification
Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel
0.01/0.001 pH display switchable
Large color graphic LCD display
JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement
USB (Host) and LAN equipped as standard specification
External printer... |
Conductivity Meter
|
|
|
DKK-TOA CM-20J
|
|
Easy-to-read LCD display
AC/DC 2-way power supply
SI unit display supported (S/m and S/cm)
Cost-effective designed in a compact size
Meas. range
0 - 20.00 S/m |
Conductivity Meter
|
|
|
DKK-TOA AA-1(for Standard) / AA-2 (for Ultrapure Water)
|
|
Single-function (no indication) conductivity analyzer for field installation
Easy installation for the one-unit amplifier and detector
Output: 4 - 20mADC
Power supply: 100VAC
Meas. range
AA-1: 0 - 2 μS/cm to 0 - 10000 μS/cm AA-2: 0 - 0.2/0.5/1.0 μS/cm
|
Conductivity Detectors with Amplifier
|
|
|
DKK-TOA COL-110
|
|
Color and turbidity can be measured simultaneously by dual wavelength with just one meter
Equipped with interactive easy-to-use color touch panel
Meas. range
Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm) |
Colorimeter/Turbidity Meter
|
|
|
DKK-TOA CFPP
|
|
Designed for oil refinery
Continuous measurement of plugging pour point which is used as indication of light oil and intermediate fraction of fuel oil A
Best suited for management of plant and product control
Explosion-proof TIIS d2G4 certified
Meas. range
-30 - +20 degrees C
|
Cold Filter Plugging Point Analyzer
|
|
|
DKK-TOA CPA-21
|
|
Designed for oil refinery
Measures cloud point of petroleum products like gas-oil continuously
Best suited for management of plant and product control
Explosion-proof TIIS d2G4 certified
Meas. range
-30 - +20 degrees C
|
Cloud Point Analyzer
|
|
|
DKK- TOA CLD-7M
|
|
Measures chloride demand of water and estimates chlorine injection level; best suited for feed forward control
Meas. range
From 0 - 5 mg/L to 10 mg/L (ppm) From 0 - 10 mg/L to 20 mg/L (ppm)
|
Chloride Demand Analyzer
|
|
|
DKK-TOA GFC-311E
|
|
Carbon Monoxide Analyzer GFC-311E
US EPA Approval
Gas filter correlation method (IR method)
High sensitivity measurement enabled with multi-reflection cell
Easy-to-use touch panel
Meas. range
0 - 5, 0 - 10, 0 - 20, 0 - 50, 0 - 100 ppm
|
Carbon Monoxide Analyzer
|
|
|
DKK-TOA CGS-12
|
|
Calibration Gas Generator CGS-12
Calibrator for SO2/NOX/CO analyzers
Built-in zero gas generator enables suction of ambient air & purification into zero gas
Concentration of span gas (calibration) is freely adjustable between 1:100 & 1:10000 of component gas concentration
|
Calibration Gas Standards Generator
|
|
|
DKK-TOA BPM-2000
|
|
Designed for oil refinery
Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc.
Adopts high resolution liquid level detecting sensor
Newly-developed FA computer embedded with large-sized, color touch panel
Explosion-proof TIIS fd2G4 certified
Meas. range
Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C)
|
Boiling Point Analyzer
|
|
|
DKK-TOA BSC
|
|
A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers
Enables sampling for analysis from the boiler
Consistent manufacturing from analyzer to sampler
Sample condition
Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min
|
Boiler Sampling System
|
|
|
DKK-TOA BMR-24
|
|
Compact and lightweight model in accordance with DIN standard
DC 24V power supply designed for 4-point alarm and 2-wire transmitters
Often used as a receiver of 2-wire or 4-wire transmitter (such as pH/ORP meters, conductivity analyzers and DO meters)
Meas. range
pH meter: pH; 0 - 14 70divisions (to be specified otherwise)
|
Bar Graph Meter Relay
|
|
|
DKK-TOA WQMS-CW
|
|
Designed for environmental water measurings such as rivers, lakes, and other water bodies
Built-in automatic cleaning and calibration function greatly reduce maintenance work
Sensor-integrated design shrinks the unit size and space-saving
Measurement items
Temperature, pH, Electrical Conductivity, Turbidity, DO(Dissolved Oxygen)
|
Automatic Water Quality Monitor
|
|
|
DKK-TOA MWB4-70
|
|
B4 size compact analyzer excellent in reliability, durability and maintainability
Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents
Equipped with interactive easy-to-use color touch panel
|
Automatic Water Quality Analyzer for City Water
|
|
|
DKK-TOA NPW-160
|
|
Automated Total Nitrogen/Phosphorus/COD Analyzer NPW-160
Measuring based on official measuring method
Multiple-wavelength detector enables measurement of total nitrogen, total phosphorus and COD simultaneously
Space-saving design attained by eliminating back piping
Drip-proof construction
Meas. range
Total nitrogen: 0 - 2 mg/L to 50 mg/L Total phosphorus: 0 - 0.5mg/L to 20 mg/L COD (UV method): 0 - 2 Abs
|
Automatic Total Nitrogen/Phosphorus/COD Analyzer
|
|