Ground continuity check of three-wire devices with high-voltage interlock Front-panel adjustable leakage current trip from 0.3 to 12 mA One-second or continuous testing Automatic failure shutdown, with visual and audible alarms Recessed high-voltage connections Front-panel NEMA 5-15R three-prong receptacle Zero start/reset in event of failure Meets UL 120-k½ requirement Available in alternate configurations: 230315 - 0-3 kV AC applied test voltage 230425 - 0-4 kV AC and 0-5 kV DC applied test voltage

Category: Megger
Created on: 15 May 2014

Front-panel adjustable leakage current trip from 0.3 to 12 mA One-second or continuous testing Automatic failure shutdown, with visual and audible alarms Recessed high-voltage connections Zero start/reset in event of failure Meets UL 120-k½ requirement Available in alternate configurations: 230315 - 0-3 kV AC applied test voltage 230415 - 0-4 kV AC applied test voltage

Category: Megger
Created on: 15 May 2014

Full conformance to latest UL and ANSI test requirements. Meter reading - not just "good/bad" indications. Ground check bypass switch permits testing of two wire or double-insulated devices. Removable lid with metal tray holds device under test. Front-panel NEMA 5-15 output receptacle, with adapters available to convert to a 20-ampere plug or twist lock up to 30-amperes

Category: Megger
Created on: 15 May 2014

Determines condition of lead-acid and NiCd Cells up to 7000 Ah On-board Pass/Warning/Fail Indications Robust, repeatable instruments On-line testing

Category: Megger
Created on: 15 May 2014

Determines condition of lead-acid and NiCd Cells up to 7000 Ah On-board Pass/Warning/Fail Indications Robust, repeatable instruments On-line testing

Category: Megger
Created on: 15 May 2014

Resolution to 0.1 µΩ on 599.9 µΩ range Standard accuracy of ±0.25% Digital Readout

Category: Megger
Created on: 15 May 2014

Five Models Grounded or ungrounded AC system check Model 510836-1 provides Bright LED indication

Category: Megger
Created on: 15 May 2014

Detector rated for transmission line voltages Continuous monitoring Electronic model with red LED and audible indication IEC conformance Available in alternate configurations: 514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole 514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole 514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole 514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line pole 514242-2 - 200 to 550 kV, Spline fitted for attachment to a universal hot line pole 514440-2 - 3.6 to 36.5 kV, 48-in. telescopic pole