GNA2044-SD-1104V2 2-CHANNEL SMOKE DETECTOR WITH 4-20MA OUTPUT & DISPLAY

Category: Smoke detectors

 

GNA2044 is a microprocessor internal 2-channel smoke detector.


GNA2044 is an environment-adaptive smoke detector which displays the concentration on the back light LCD by receiving the serial signals from two sensors and by processing them in the digital mode, and performs the variety of local functions in digital process mode.
Also, it can ensure the effective remote control by stably outputting the analog serial signals to external control unit such as PLC/DDC.


As one of big advantages of GNA2044, it can be suitably applicable for various purposes by processing the sensible signals detected by ionization sensor by microprocessor stably and accurately.
Because the existing smoke detectors have been mostly applied only for a fire alarm, it is general that they don’t ensure an accuracy and safety for a utility of industrial field.
GNA2044 is designed to ensure a sensibility and safety simultaneously by controlling the sensible ionization sensor with an industrial detector technology.

 

[ Features ]
Low Concentrated Smoke Detection
It is suitable to a small quantity smoke detection because it is designed for a purpose of supporting the safety function of industrial automation equipment.
Ionization sensor : Ionization sensor using the current change when the smoke is combined in the ion created by radial rays can detect very low concentrated smoke.
LCD Display with Back-Light
Local Alarm
It can set the alarm concentration by microprocessor. When the detection concentration is larger than the alarm concentration, over 80㏈ alarm sound is generated. It informs whether the smoke occurs.
User Selection Menu
It is organized suitably for the purpose of use because various artificial intellectuals are provided by microprocessor. It maximizes the effect of detection function because various functions such as alarm concentration setting, detection range setting, and alarm reset setting are properly used.
Two–Channel Detection
It can monitor the maximum 2 ionization sensor at the same time and can extend the detection space.
 
[ Specification ]
 
 
Classification  
General Type 1 or 2 Channel Monitoring
Product Type Wall type
Detection Principle Ionizations Smoke Chamber
Detection Type Diffusion Type
Response Time Less 5 sec.
Detection Range 0 ~ 500 Pcs/L
External Output 4 ~ 20㎃
Power Source DC 24V
Alarm Type High / Low 2 Step Alarm – User setting
Alarm Reset Manual or automatic – User selection
Signal Wire CVVS & CVVSB 1.25sq x 3 Wire - Shield Type
Available Current 500㎃. Maximum
System Initialization Time Less 50 sec.
External Structure Monitoring Unit - Metal, Sensor Unit - Aluminum
Temperature/Humidity -20℃~ 50℃ / 0 ~ 95% RH (Non-Condensing)
Process Digital Process

[ Features ]

Description: http://www.gasdna.com/en/images/bl01.jpgLow Concentrated Smoke Detection

It is suitable to a small quantity smoke detection because it is designed for a purpose of supporting the safety function of industrial automation equipment.

Description: http://www.gasdna.com/en/images/bl01.jpgIonization sensor : Ionization sensor using the current change when the smoke is combined in the ion created by radial rays can detect very low concentrated smoke.

Description: http://www.gasdna.com/en/images/bl01.jpgLCD Display with Back-Light

Description: http://www.gasdna.com/en/images/bl01.jpgLocal Alarm

It can set the alarm concentration by microprocessor. When the detection concentration is larger than the alarm concentration, over 80 alarm sound is generated. It informs whether the smoke occurs.

Description: http://www.gasdna.com/en/images/bl01.jpgUser Selection Menu

It is organized suitably for the purpose of use because various artificial intellectuals are provided by microprocessor. It maximizes the effect of detection function because various functions such as alarm concentration setting, detection range setting, and alarm reset setting are properly used.

Description: http://www.gasdna.com/en/images/bl01.jpgTwo–Channel Detection

It can monitor the maximum 2 ionization sensor at the same time and can extend the detection space.

 

 

 

 

 

 

 

 

 

 

 

 

[ Specification ]

 

Classification

General Type

1 or 2 Channel Monitoring

Product Type

Wall type

Detection Principle

Ionizations Smoke Chamber

Detection Type

Diffusion Type

Response Time

Less 5 sec.

Detection Range

0 ~ 500 Pcs/L

External Output

4 ~ 20

Power Source

DC 24V

Alarm Type

High / Low 2 Step Alarm – User setting

Alarm Reset

Manual or automatic – User selection

Signal Wire

CVVS & CVVSB 1.25sq x 3 Wire - Shield Type

Available Current

500. Maximum

System Initialization Time

Less 50 sec.

External Structure

Monitoring Unit - Metal, Sensor Unit - Aluminum

Temperature/Humidity

-20~ 50 / 0 ~ 95% RH (Non-Condensing)

Process

Digital Process

Location