DR FLU 410 GROUP THERMAL/AUTO-SNAPSHOTS FEVER DETECTION SYSTEM - USA (FLI0021M)
|
|
DR FLU 410 (FLI0021M) GROUP THERMAL/AUTO-SNAPSHOTS FEVER DETECTION SYSTEM - FROM USA
Built-in AI face detection moduleMeasurement distance - 2.6 to 10.5 feetCan screen entire groups of people simultaneouslyAutomatically detects and locks onto face for temperature measurementGenerates sound and turns red when abnormal temperature is detectedHelps prevent false positivesIntelligently shields non-facial high temperature sources in scene, such as a coffee mugAutomatically collects facial... |
Body/Forehead Thermometers / Body Fever Screening Devices
|
|
|
DR FLU 250 Temperature-Measuring face recognition Terminal Product (KKI0102M)
|
|
Product overview
DR FLU 250 is a high-performance embedded binocular temperature-measuring face recognition terminal. The terminal integrates the functions of off-line face recognition, temperature detection, mask recognition, identity verification, on-site face collection, blacklist early-warning, photo taken after passing, active object detection. It adopts WDR HD face recognition camera, which is fully adapted to harsh environment such as strong light, back light and weak light, with... |
Body/Forehead Thermometers / Body Fever Screening Devices
|
|
|
DWY001 to DWY008 F-Shape Stainless Steel Pitot tubes from USA
|
|
The SERIES F Shape Stainless Steel Pitot Tube is constructed from corrosion resistant stainless steel with permanently etched insertion depth graduations for a lifetime of service. The static pressure port is parallel to the sensing tube to allow quick, easy alignment of the tube with air flow. A universal model fits the user supplied 3/4" schedule 40 pipe in any length.
Model
Description
DWY001-160-12
Stainless steel Pitot tube, 5/16" 8mm dia., 12-5/8" 35cm insertion... |
F-Shape Pitot Tubes (Prandtl)
|
|
|
DWY009 to DWY014 Straight Stainless Steel Pitot tubes from USA
|
|
Straight Design, Accurate Positioning
These Straight Stainless Steel Pitot Tube is constructed from corrosion resistant stainless steel with permanently etched insertion depth graduations for a lifetime of service. The static pressure port is parallel to the sensing tube to allow quick, easy alignment of the tube with air flow. The straight design allows for easy insertion into ducts through grills and pressure taps, as well as aids in positioning in hard to reach locations where a hook... |
F-Shape Pitot Tubes (Prandtl)
|
|
|
DKK-TOA GNC-224-1
|
|
Flue Gas Hydrogen Chloride Analyzer GNC-224-1
Continuous measurement of flue gas hydrogen chloride concentration produced in incineration plants by ion electrode method
Small size chloride ion electrode and auto-cleaning function equipped
Easy installation and maintenance attained with front panel operation
Meas. Range
0 - (50 - 2000) ppm 0 - (10 - 50) ppm (optional)
|
Flue Gas Hydrogen Chloride Analyzer
|
|
|
DKK-TOA GCO-200
|
|
Flue Gas CO/O2 Analyzer GCO-200
CO/O2 analyzer with an electric electrolysis CO sensor and a galvanic battery adapted O2 sensor
Ease of maintenance, cost reduction attainable with simple constructed unit
Meas. range
CO: 0 - 200 to 2000 ppm (setting available at 100 ppm intervals)(assignable) O2: 0 - 25%
|
Flue Gas CO/O2 Analyzer
|
|
|
DKK-TOA CGS-12
|
|
Calibration Gas Generator CGS-12
Calibrator for SO2/NOX/CO analyzers
Built-in zero gas generator enables suction of ambient air & purification into zero gas
Concentration of span gas (calibration) is freely adjustable between 1:100 & 1:10000 of component gas concentration
|
Calibration Gas Standards Generator
|
|
|
DKK-TOA GFC-311E
|
|
Carbon Monoxide Analyzer GFC-311E
US EPA Approval
Gas filter correlation method (IR method)
High sensitivity measurement enabled with multi-reflection cell
Easy-to-use touch panel
Meas. range
0 - 5, 0 - 10, 0 - 20, 0 - 50, 0 - 100 ppm
|
Carbon Monoxide Analyzer
|
|
|
DKK-TOA GUX-313E
|
|
Ozone Analyzer GUX-313E
US EPA Approval
Continuous measurement of O3 concentration by using UV photometry method
Easy-to-use touch panel
Meas. range
0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Ozone Analyzer
|
|
|
DKK-TOA GFS-312E
|
|
Sulfur Dioxide Analyzer GFS-312E
US EPA Approval
Continuous measurement of SO2 by using Ultraviolet fluorescence method
Improved optical system reduces the impact from interfering substances
Easy-to-use touch panel
Meas. range
0 - 0.05, 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Sulfur Dioxide Analyzer
|
|
|
DKK-TOA GLN-314E
|
|
Nitrogen Oxides Analyzer GLN-314E
US EPA Approval
Chemical luminescence method
Alternating measurement of nitric monoxide (NO) and nitrogen oxides (NOx) ensures stable and continuous measurement of minute amounts of nitrogen oxides in the air
Easy-to-use touch panel
Meas. range
0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0, 0 - 2.0 ppm
|
Nitrogen Oxides Analyzer
|
|
|
DKK-TOA FPM-222
|
|
US EPA Approval
Beta ray attenuation method (mass concentration)
Small and semi-permanent semiconductor detector is used to detect the Beta ray
Easy calibration with the calibration film
Meas. range
0 - 1000, 0 - 5000 μg/m3 (0 - 1, 0 - 5 mg/m3)
|
Particulate Monitor
|
|
|
DKK-TOA FPM-377
|
|
PM2.5 Monitor FPM-377
Environment Ministry (JAPAN) Approval
Beta ray attenuation method (mass concentration)
Heater type dehumidifier
VSC cyclone (USEPA approval)
Outdoor type and indoor type available
Meas. range
0 - 500, 0 - 1000, 0 - 5000 μg/m3
|
Particulate Monitor
|
|
|
DKK-TOA SODL-1600
|
|
Oil Film Detector (Explosion-Proof Model) SODL-1600
Robust aluminum pressure resistance explosion-proof model
Oil film is detected by measuring differences of the amount of laser reflectance of oil and water
With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively
Contact-free and easy maintenance
Detectable range
0.3 - 3 m
|
Oil Film Detector
|
|
|
DKK-TOA OF-1600
|
|
Oil film is detected by measuring differences of the amount of LED reflectance of oil and water
Small and lightweight design
Contact-free and easy maintenance
Detectable range
About 0.5 m
|
Oil Film Detector
|
|
|
DKK-TOA ODL-1610A
|
|
Oil Film Detector (Long-Distance Model) ODL-1610A
Enables oil film detection even if the surface of sample is 10m away from the detecting cell
Ideal for difficult conditions such as turbulent water and places where is difficult to setup near-water detectors
Contact-free and easy maintenance
Detectable range
0.3 - 10 m
|
Oil Film Detector
|
|
|
DKK-TOA ODL-1600
|
|
Oil film is detected by measuring differences of the amount of laser reflectance of oil and water
With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively
Contact-free and easy maintenance
Detectable range
0.3 - 3 m
|
Oil Film Detector
|
|
|
DKK-TOA CRM-1600
|
|
Automated intermittent monitoring unit; Spectrometric Method using 1,5-Diphenylcarbazide
Stuck of the electromagnetic valve has been improved with rotating measurement cell
Designed for discharged wastewater of plating factory, river water quality and related fields
Meas. range
0 - 0.5/1.0 mg/L (2-ranges)
|
Hexavalent Chromium Monitor
|
|
|
DKK-TOA NHMS-4
|
|
Simple measurement with just an ion electrode
Enables continuous ammonium ion measurements in discharged industrial wastewater, river and water purification plants
Automatic cleaning and calibration function ensures stable measurement
Easy-to-use touch panel
Low-concentration calibration function available
Meas. range
0.05 - 5/0.1 - 10/1 - 100 mg/L
|
Ammonium Ion Monitor
|
|
|
DKK-TOA FBM-100A(Panel Type)
|
|
Simplified Fluoride Ion Monitor FBM-100A(Panel Type)
Compact DIN 96 size unit
Quick and continuous detection of free fluoride ion concentration
Monitors the effluent treatment processes and final effluent from semiconductor factories, etc.
Meas. range
0 - 99.9/999/9990 mg/L
|
Simplified Fluoride Ion Monitor
|
|