Fluke 1507 Insulation Resistance Multimeter
|
|
Insulation Test Range: 0.01MΩ to 10GΩ
Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V
Automatic calculation of Polarization Index and Dielectric Absorption Ratio saves both time and money
Compare (Pass/Fail) function makes repetitive tests simple and easy
Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test... |
Megohmmeters
|
|
|
Fluke 1503 2000 MΩ Insulation Resistance Multimeter
|
|
Insulation Test Range: 0.1MΩ to 2000MΩ
Insulation Test Voltages: 500 V, 1000 V
Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance:... |
Megohmmeters
|
|
|
Fluke 1577 and 1587 Insulation Multimeters
|
|
Large display with backlight
Insulation test (1587: 0.01 Mohm to 2 Gohm), (1577: 0.1 Mohm to 600 Mohm)
Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V), (1577: 500 V, 1000 V)
Live circuit detection prevents insulation test if voltage> 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (W), Continuity
Auto power off to save battery power
CAT III 1000 V,... |
Megohmmeters
|
|
|
Fluke 707 Loop Calibrator
|
|
Large display and simple, quick-click interface for easy one-handed operation
Simultaneous mA and % readout for quick, easy, interpretation of readings
mA accuracy of 0.015%, superior to other loop calibrators in this price range
1µA resolution for mA source, simulate and measure
Push button 25% steps for fast, easy linearity checks
0-100% "span check" for fast confirmation of zeroand span
Measures V dc to 28 V
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs... |
Loop Calibrators
|
|
|
Fluke 705 Loop Calibrator
|
|
A large display and simple, pushbutton interface for ease of use.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.02%
Push button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls.
"Span Check" for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a... |
Loop Calibrators
|
|
|
Fluke RLD2 Leakage Detector HVAC/R Flashlight
|
|
Six UV LEDs (395 nm wavelength) detect leak detection dyes
Laser pointer clearly locates center of the UV field for accuracy
Three LED flashlight with 100,000 hour LED life
Operating temperature 0 °C to 50 °C
Four operating modes: flashlight, UV light, laser light, UV/laser light combination
Convenient detachable key chain carabineer and AAA battery included
|
Leak Detectors
|
|
|
Fluke 424D 100m Range Laser Distance Meter
|
|
Improved visibility with backlit screen
Ability to measure up to 100 meters (330 ft)
Tripod mode allows you to mount to a tripod for measuring long distances
Stake out function
Reduction of estimation errors, saving both time and money
Instant measurement with one-button operation
Easy addition and subtraction function
The most advanced laser technology for distance measurement
Simple one-button operation to instantly measure distance between two objects
Bright laser for easy... |
Laser Distance Meters
|
|
|
Fluke 419D 80m Range Laser Distance Meter
|
|
Improved visibility with backlit screen
Ability to measure up to 80 m (260 ft)
Tripod mode allows you to mount to a tripod for measuring long distances
Stake out function
Reduction of estimation errors, saving both time and money
Instant measurement with one-button operation
Easy addition and subtraction function
The most advanced laser technology for distance measurement
Simple one-button operation to instantly measure distance between two objects
Bright laser for easy targeting... |
Laser Distance Meters
|
|
|
Fluke 414D 50m Range Laser Distance Meter
|
|
Reduction of estimation errors, saving both time and money
Instant measurement with one-button operation
Easy addition and subtraction function
The most advanced laser technology for distance measurement
Simple one-button operation to instantly measure distance between two objects
Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
Bright laser for easy targeting even at longer distances
Quick calculation of area (square feet/meters) and volume
Easy addition and subtraction... |
Laser Distance Meters
|
|
|
Fluke 1555 Insulation Resistance Tester 10 kV
|
|
Test voltages to up 10 kV
CAT III 1000 V, CAT IV 600 V safety rating
Warning function alert for increased user safety
Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
Up to 99 memory locations
Over 750 tests between battery charges
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI)
Guard system eliminates the effect of surface leakage current on high-resistance measurements
Large digital/analog LCD
Capacitance and... |
Insulation Testers
|
|
|
Fluke 1550C Insulation Resistance Tester 5 kV
|
|
Test voltages to up 10 kV
CAT III 1000 V, CAT IV 600 V safety rating
Warning function alert for increased user safety
Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
Up to 99 memory locations
Over 750 tests between battery charges
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI)
Guard system eliminates the effect of surface leakage current on high-resistance measurements
Large digital/analog LCD
Capacitance and... |
Insulation Testers
|
|
|
Fluke 1507 Insulation Resistance Multimeter
|
|
Insulation Test Range: 0.01MΩ to 10GΩ
Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V
Automatic calculation of Polarization Index and Dielectric Absorption Ratio saves both time and money
Compare (Pass/Fail) function makes repetitive tests simple and easy
Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test... |
Insulation Testers
|
|
|
Fluke 1503 2000 MΩ Insulation Resistance Multimeter
|
|
Insulation Test Range: 0.1MΩ to 2000MΩ
Insulation Test Voltages: 500 V, 1000 V
Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance:... |
Insulation Testers
|
|
|
Fluke 1577 and 1587 Insulation Multimeters
|
|
Large display with backlight
Insulation test (1587: 0.01 Mohm to 2 Gohm), (1577: 0.1 Mohm to 600 Mohm)
Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V), (1577: 500 V, 1000 V)
Live circuit detection prevents insulation test if voltage> 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (W), Continuity
Auto power off to save battery power
CAT III 1000 V,... |
Insulation Testers
|
|
|
Fluke Infrared (IR) Windows
|
|
If you have an onsite infrared program already or planning to establish one you should consider installing Fluke IR Windows. Fluke IR Windows will increase:
Efficiency – cut down the time needed to conduct regular inspections
Safety – increase your employees safety by not exposing them to live equipment
Productivity – cuts down the number of technicians needed to conduct inspections
NFPA 70E and local safety regulation compliance is easier with Fluke IR Windows
Fluke IR Windows... |
Infrared Windows
|
|
|
Fluke VT04 14 °F to 482 °F Visual IR Thermometer with PyroBlend Plus optic
|
|
Detect issues instantly with built-in digital camera
No training required; Fully automatic with built-in intelligence
True pocket size design
Breakthrough affordability: Half the cost of infrared cameras that require training and software
Exclusive thermal heat map blending overlay
Blend digital and thermal images to instantly show the exact location of the issue
Blend between 0 %, 25 %, 50 %, 75 %, and full thermal with one button
Powerful resolution with PyroBlend Plus... |
Infrared Thermometers
|
|
|
Fluke VT02 Visual Infrared (IR) Thermometer 10°C to +250°C (14°F to 482°F) Temp. Range, 2°C Accuracy
|
|
-10°C to +250°C (14°F to 482°F) Temperature Measurement Range
2°C or 2% (at 25 °C nominal, whichever is greater) Accuracy
Detect issues instantaneously with digital and thermal blended images
Pinpoint hot and cold spots with temperature markers
Perform inspections up to 30 times faster than traditional infrared thermometers
Document and communicate problems efficiently with SmartView reporting software
|
Infrared Thermometers
|
|
|
Fluke 572-2 High Temperature Infrared Thermometer
|
|
Measure -30 °C to 900 °C (-22 °F to 1652 °F)
60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
Current Temperature plus MAX, MIN, DIF, AVG temperature displays
Compatible with all standard mini-connector K-type thermocouples, including ones you already own and have installed.
High and low temperature alarm
USB 2.0 computer interface cable
FlukeView Forms Documenting Software
Two-year warranty
|
Infrared Thermometers
|
|
|
Fluke 572, 572CF, 574, 574CF and 574NI Infrared Non-Contact Thermometer
|
|
Temperature range of -30 to 900 ºC (–25 to 1600 ºF)
Point and shoot
Current, MIN & MAX
Adjustable emissivity
High alarm with flashing laser/LED and buzzer
Automatic backlight
Trigger lock
Displays probe temperature thermocouple K (574 only)
100 Data logging points (574 only)
2 AA Batteries
|
Infrared Thermometers
|
|
|
Fluke 568EX -40°C to 800°C Intrinsically Safe Infrared Thermometer
|
|
Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world
Measure -40 °C to 800 °C (-40 °F to 1472 °F)
Conductive Case for carrying the IR thermometer safely into hazardous area
Easily access advanced features with the soft-key buttons and graphical display
Measure small objects from further away, with a distance-to-spot ratio of 50:1
Compatible with mini-connector K-type thermo-couple... |
Infrared Thermometers
|
|