SEW-Taiwan

SEW New

  • Filter
Created on: 20 February 2014

FEATURES ● The RCB-1 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 2M. 7M. 10M. 20M. 30M. 50M. 100M. 200M. 500M. 1G. 2G. 5G. 10G. 20G. 50G. 100G. 200G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 5200g...

Created on: 20 February 2014

3 1/2 digit liquid crystal display. ● 200mV and 2V full scale input sensitivity. ● Single Battery operated 9V supply or ±5V DC power supply (Dual     supply). ● Built-in low battery indication and automatic polarity indication. ● Decimal point selectable. ● Low power dissipation Typically less than 20mV. ● High input impedance (> 1M ohm). ● Guaranteed zero reading for 0 volts input on all scales. ● True differential input or single-ended input. ● Self mountable with optional mounting bezel. ● Low cost high performance. ● EN 50081-1 EN 50082-1 EN 55022 EN 61000-4-2 IEC 801-3

Created on: 20 February 2014

FEATURES ● The 880 AT is a simplified Version of an appliance tester which use    low voltage and low current to perform it's checks.● Application Example   The appliance is plugged into the mini appliance checker, then the   probe make contact with the protective conductor.● Other appliance checking   Washing Machine Toaster Iron Dish Washer   Stove     SPECIFICATIONS       ELECTRICAL       Resistance Ranges    The L-E led will lit when the resistance between Line    to Earth is lower than 1MΩ ±5% .    The N-E led will lit when the resistance between Neutral to Earth is lower    than 1MΩ±5%  The EARTH BOND led will lit when the resistance between the EARTH to the Probe is higher than 10Ω±5% . Test Current    Line to Earth test current is 9uA maximum.    Neutral to Earth test current is 9uA maximum.    Earth to Probe test current is 2.3mA maximum. Maximum...

Created on: 20 February 2014

1000/5A - 3000/5A ● 10-15V A ● Class 1 ● Insulation 600V

Created on: 20 February 2014

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS Output voltage H terminal: AC 400V (± 20%) L terminal: AC 100V (± 20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 124(L) × 69(W) × 42(D)mm Weight (battery included) Approx. 305g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

Created on: 18 February 2014

● Microprocesser-controlled.● Earth testing at 2Ω, 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test.● 3-Wire test.● 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● Robust, compact and easy-to-carry.     SPECIFICATIONS       Measuring ranges Earth Resistance 0-2Ω / 0-20Ω / 0-200Ω / 0-2kΩ Earth Voltage 0-300V AC Accuracy Earth Resistance ±2%rdg ± 3dgt Earth Voltage ±2%rdg ± 3dgt Earth resistance resolution 0-2Ω : 0.01Ω 0-20Ω : 0.1Ω 0-200Ω : 1Ω 0-2kΩ : 10Ω Temperature & humidity Operating: 0°C~40°C ≤80% R.H. Storage: -10°C~50°C ≤80% R.H. Dimensions 250(L) x 190(W) x 110(D)mm Weight (battery included) Approx. 1430g Power source 1.5V (AA) x 8 Safety standards EN 61010-1 CAT IV 300V EN 61557-1 EN 61557-5 EN 61326-1

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.     SPECIFICATIONS       Test voltage (DC V) 5000V 10000V Measuring ranges 0-200GΩ 0-400GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries

Created on: 19 February 2014

FEATURES ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.     SPECIFICATIONS       Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ Continuity     Range 0.01Ω~1999Ω Voltmeter     AC V 0-700V DC V 0-950V PI Function ˇ DAR Function ˇ Metal Oxyde Varistor ˇ Gas Arrester Voltage ˇ