FEATURES ● 4000 counts.● Voltage measurement, current measurement, resistor    measurement, frequency counter, capacitor measurement.● Bargraph indication.● Range change function.● Data hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Diode measurement.● Max / Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal    parts, shielded banana plugs and recessed input terminals.     SPECIFICATIONS       DC Voltage     Ranges Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+3dgt) 4V 1mV 40V 10mV 400V 100mV 600V 1V  ․Overload protection : 650V DC AC Voltage     Ranges Resolution Accuracy 400mV 0.1mV ±(0.5%rdg+3dgt) 4V 1mV ±(1.5%rdg+3dgt) 40V 10mV 400V ...

Created on: 20 February 2014

FEATURES ● 3½ digit, high contrast LCD, with a maximum display of 1999.● Automatic polarity indication, zero adjust.● Low battery (BAT) indication.● Over range indication: highest digit of (1) or (-1). ANALOG DISPLAY ● Large 90º wide and 84mm long mirror scale. (adapted to digital,   analog maximum indication 2400).● Peak hold mode.● Shock and vibration resistant TAUT BAND movement.● Switch selection normal (left hand side) zero or center (galvo-mode)   zero. Polarity + or -, pointer turn to right hand side, avoid opposite   direction.● Centre zero and ohm zero : automatic● Dimensions: 167(L) × 102(W) × 39(D)mm     SPECIFICATIONS       DC...

Created on: 20 February 2014

FEATURES ● High quality movement.● Compact and lightweight; easy to use and store.● Mirror scale: for easier viewing & reading.● Built-in stand makes reading and measuring easy.● 200μA full scale value.● Fuse-protected.● Low battery indication.     SPECIFICATIONS   AC Leakage Current     Measuring range 0.3mA-1mA-3mA-10mA-30mA Accuracy ±2% of full scale Input resistance 1.5kΩ AC Voltage     Measuring range 0-300 / 0-600V Accuracy ±2% of full scale Input resistance 300V     1MΩ 600V     2MΩ General     Low battery indication Battery check indicate good battery from 7Vdc to 9Vdc during a load test of 2mA Dimensions 160(L) × 100(W) × 45(D)mm Weight (battery included) Approx. 360g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN 61326-1

Created on: 20 February 2014

FEATURES ● Big-size LCD (112 x 59mm)● Back light function.● Analog scale with Bar-graph for viewing. (100 bars)● 10000 counts (high resolution).● DCV Ranges: 99.99mV~999.9V. ● 5 manual ranges controlled by rotary switch.● Data Hold function● Low battery indication● 9V power supply● Best resolution of 0.01mV (10uV)● Precision meter for factory maintenance, field servicing and   educational purposes.● Easy to carry handle that doubles as a convenient stand.

Created on: 21 February 2014

AL-19C-1 For 2mm probe tip● AL-19C-3 For 4mm banana plug● AL-19C-5 For 2mm probe tip (only for exposed 4mm probe tip)● Rating :  EN 61010-031:2002 + A1:2008                CAT III 1kV 10A                 CAT IV 600V 10A

Created on: 18 February 2014

● 8 voltage settings: 240Vac, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, and 275kV.● High bright LED visual indication.● Sound indication.● Easy-to-prove method.● Self-test selection.● Use 3 × 1.5V “C” batteries.● High impact nylon casing.● Non-contact work by proximity.● Compatible with most link sticks.● Lightweight, robust, & compact.● Suitable for indoor and outdoor use.● Detects low voltage on any systems.● Easy access to batteries.● No special parts needed.● Meets EN 61326-1  EN 55011  EN 61000-4-2  EN 61000-4-3● United States Design Patent : US D474, 705 S● Special ranges are available upon request.

Created on: 18 February 2014

● Microprocesser-controlled. ● Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ.● Capable of measuring earth voltage.● 3 ¾ digit (4000 counts).● LCD backlight display.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Data hold function.● Relative function.● Auto power-off function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS Measuring ranges Earth Resistance 0~40Ω / 0~400Ω / 0~4kΩ Earth Voltage 0~400V (40~500Hz) Accuracy Earth Resistance ±(2%rdg+3dgt) Earth Voltage ±(2%rdg+3dgt) Earth resistanceresolution 0~40Ω : 0.01Ω 0~400Ω : 0.1Ω 0~4kΩ : 1Ω Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Dimensions 163(L) x 102(W) x 50(D)mm Weight (battery included) Approx. 440g  Power source 1.5V (AA) x 6 Safety standards EN 61010-1 CAT IV 400V EN 61326-1 EN 61557-1 EN 61557-5

Created on: 19 February 2014

FEATURES ● Microprocessor-controlled.● 68 x 34mm large LCD display.● 3½ digital LCD (2000 counts) a LCD indicated instrument for    insulation(MΩ), continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● Auto ranging.● Auto power off function.● Auto data hold function.● Rel function (ohm only)● Continuity buzzer.● External AC voltage warning.● Automatic circuit discharge.● BS 16th edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20.00MΩ 0-200.0MΩ 0-2000MΩ Output voltage open circuit Rated test voltage +10% Accuracy 20MΩ : ±(1.5%rdg+2dgt) 200MΩ : ±(2.5%rdg+2dgt) 2000MΩ : ±(5%rdg+3dgt) Resolution 0-20.00MΩ : 10kΩ 0-200.0MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-500V Resolution 1V Accuracy ±(1.5%rdg+3dgt) Continuity     Ranges 20Ω / 200Ω / 2000Ω Resolution 0-20Ω : 0.01Ω...