Created on: 19 February 2014

FEATURES ● High contrast OLED display.● Designed for viewing in the dark, for mining industry.● Microprocessor-controlled.● Indicates phase rotation● Indicates phase presence● TEST for disconnection sensitivity● Battery status indicator● Measures Voltage Phase to Earth● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Phase rotation and presence does not require battery to indicate.     SPECIFICATIONS       Nominal voltage for phase presence frequency range 100Vac to 450Vac 10Hz to 400Hz Rotary field direction phases frequency range 100 to 450Vac 2Hz to 400Hz Overload protection 550V (between all terminal) Over voltage protection Class III - 450V towards ground Current settings 999mAac /50Hz-60Hz Phase start selection 0º and 180º Phase polarity trip Indicator ˇ Operating voltage (L-E) referenced to earth 220Vac to 317Vac Timer resolution 1ms (Max....

Created on: 19 February 2014

FEATURES Cable Tracer ● Trace wires or cables.● Volume control.● Tip & Ring identification.● 2 bi-colored LEDs ( Line 1 & Line 2).● Tone speed selection : Fast & Slow.● A phone jack is designed for headset or handset.   (Amplifier probe) Digital Multimeter ● 4000 counts.● ACV, DCV.● Ohm, Diode, & Continuity testing.● Auto-range.● Data hold.● Low battery indication.● Select function.● Auto-off.     SPECIFICATIONS   AC Voltage     Range Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+5dgt) 4V 1mV 40V 10mV 400V 100mV 750V 1V DC Voltage     Range Resolution Accuracy 400mV 0.1mV ±(0.5%rdg+3dgt) 4V 1mV 40V 10mV 400V 100mV 1000V 1V Resistance     Range Resolution Accuracy ...

Created on: 20 February 2014

FEATURES ● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.     SPECIFICATIONS       GENERAL     Maximum Rating between Poles 450V Category IV FUSES     Type HBC/HRC Rate of Rupture Slow Blow Current Rating 500mA    Voltage Rating 600V Quantity 2 VOLTMETER The Neon Voltage Scale Indication Neon lit when Voltage > or = 110V Neon lit when Voltage > or = 220V Neon...

Created on: 20 February 2014

Easy to read long-scales and pointer-indications can easily be    read from a distance. ● Full Scale Deflection:250° ● Accuracy: Class 1.5 ● Length:183 mm ● Case And Composition:    Acrylic Resin cover, plastic body and terminal, Four studs mounting. ● Color:White scale plate, black terminal plate, black meter body. ● Pointer:Sword-type in black color.

Created on: 21 February 2014

138 x 167 x 47mm

Created on: 18 February 2014

● Triangular-shaped design keeps the sections aligned during extension and retraction.● Push button release for stick extension and retraction. ● Telescopic design allows for easy assembly, storage and transportation.● Withstands voltage rating of 100kV from 30cm for 5 minutes.      ● Universal end fitting accepts a wide variety of standard attachments.● Highly visible  yellow tip section.● Easy-to-replace sections.● Carrying bag included.  ● Optional integrated height measurement scale.● Complies with IEC 62193 safety standard.

Created on: 19 February 2014

FEATURES ● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Delectric Absorbtion Ration (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off   SPECIFICATIONS   Test voltage From 500Vdc to 10kVdc Adjustable in 500V Steps Preset buttons 1kV, 2.5kV, 5kV, 10kV Measuring range 800kΩ-500GΩ (auto-ranging) Accuracy ±5% ± 2 digits Output power limit 1W Voltage regulation Selected Voltage +20%-5% of nominal value unless current limited. Meaning that if output current is too high, the voltage will...

Created on: 20 February 2014

FEATURES ● Voltage test: 12V to 690V AC/DC (7 LEDs) with indication by   buzzer.● Voltage range: 12V, 24V, 50V, 127V, 230V, 400V, 690V.● Polarity test: LED +/-● Audible continuity test● Self-test button to ensure proper function of the device prior to   testing.● Waterproof design, protection class: IP54● Phase / Neutral identification● Integrated storage clips for test probe.● Rubberized injection molding.     SPECIFICATIONS       Voltage test 12V to 690V AC/DC Voltage range AC : 12V,24V,50V,127V,230V,400V,690V DC : 12V,24V,50V,127V,230V,400V,690V Flashlight ––– Working frequency 40 to 400 Hz Voltage protection 1000V DC / 700V AC Continuity range 6kΩ Resistance range 6kΩ,60kΩ,300kΩ Operating temperature 0℃ to 40℃ Operating humidity 80% R.H. Probe distance 19mm apart Dimensions 206(L) x 58(W) x 42(D)mm Weight (battery included) Approx. 190g Power source 9V(6F22) x 1 Safety standard EN 61010-1 CAT III 600V EN 61243-3 EN...