SEW-Taiwan

Various Instruments

  • Filter
Created on: 20 February 2014

FEATURES ● Voltage test: 12V to 690V AC/DC (7 LEDs) with indication by   buzzer.● Voltage range: 12V, 24V, 50V, 127V, 230V, 400V, 690V.● Polarity test: LED +/-● Audible continuity test● Self-test button to ensure proper function of the device prior to   testing.● Waterproof design, protection class: IP54● Phase / Neutral identification● Integrated storage clips for test probe.● Rubberized injection molding.     SPECIFICATIONS       Voltage test 12V to 690V AC/DC Voltage range AC : 12V,24V,50V,127V,230V,400V,690V DC : 12V,24V,50V,127V,230V,400V,690V Flashlight   ˇ Working frequency 40 to 400 Hz Voltage protection 1000V DC / 700V AC Continuity range 6kΩ Resistance range 6kΩ,60kΩ,300kΩ Operating temperature 0℃ to 40℃ Operating humidity 80% R.H. Probe distance 19mm apart Dimensions   195(L) x 56(W) x 35(D)mm Weight (battery included) Approx. 214g Power source 9V(6F22) x 1 Safety standard EN 61010-1 CAT III 600V EN 61243-3 EN...

Created on: 20 February 2014

FEATURES ● Voltage test: 12V to 690V AC/DC (7 LEDs) with indication by   buzzer.● Voltage range: 12V, 24V, 50V, 127V, 230V, 400V, 690V.● Polarity test: LED +/-● Audible continuity test● Self-test button to ensure proper function of the device prior to   testing.● Waterproof design, protection class: IP54● Phase / Neutral identification● Integrated storage clips for test probe.● Rubberized injection molding.     SPECIFICATIONS       Voltage test 12V to 690V AC/DC Voltage range AC : 12V,24V,50V,127V,230V,400V,690V DC : 12V,24V,50V,127V,230V,400V,690V Flashlight ––– Working frequency 40 to 400 Hz Voltage protection 1000V DC / 700V AC Continuity range 6kΩ Resistance range 6kΩ,60kΩ,300kΩ Operating temperature 0℃ to 40℃ Operating humidity 80% R.H. Probe distance 19mm apart Dimensions 206(L) x 58(W) x 42(D)mm Weight (battery included) Approx. 190g Power source 9V(6F22) x 1 Safety standard EN 61010-1 CAT III 600V EN 61243-3 EN...

Created on: 20 February 2014

FEATURES ● The RCB-3-1T is used to verify and proof any High Voltage    Insulation Testers. It can be utilized to calibrate all High Voltage    Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator    too, therefore, SEW started manufacturing the RCB for special    customers.     SPECIFICATIONS Resistance ranges (Ω) 1M. 10M. 100M. 1G. 10G. 100G. 1T Resistance tolerances ±1%(F) Tolerance  ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

Created on: 20 February 2014

FEATURES ● The RCB-3-1T is used to verify and proof any High Voltage    Insulation Testers. It can be utilized to calibrate all High Voltage    Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator    too, therefore, SEW started manufacturing the RCB for special    customers.     SPECIFICATIONS Resistance ranges (Ω) 1M. 10M. 100M. 1G. 5G. 10G. 100G. 1T Resistance tolerances ±1%(F) Tolerance  ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

Created on: 20 February 2014

FEATURES ● The RCB-3 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 10M. 100M. 1G. 5G. 10G. 100G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

Created on: 20 February 2014

FEATURES ● The RCB-1 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 2M. 7M. 10M. 20M. 30M. 50M. 100M. 200M. 500M. 1G. 2G. 5G. 10G. 20G. 50G. 100G. 200G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 5200g...

Category: Power Meter
Created on: 20 February 2014

FEATURES ● Determine the running cost your appliances.● Make informed decisions when purchasing appliances and   equipment.● Reduce your electricity bill.● Measure Voltage, Current, Power, Volts, Amps, Power Factor, and   Greenhouse Gas Emissions.● Calculate electrical expenses by day, week, month, and even an   entire year.     SPECIFICATIONS           Item Range Units Accuracy PM-10 PM-15 AC Voltage 100-240 V rms ±1% AC Current 10 15 A rms ±1% Power 0-2500 0-3750 W ±1% Apparent Power 0-2500 0-3750 VA ±1% Power Factor 0.001-1   Watt /(Vrms* Arms) Frequency 45-65 Hz ±1% Cost 0-9999999 $   Energy 0-99999 kWh   Gas 0-999999 kg   Cost Setting 0-99.999 kWh,cents/kWh   Gas Setting 0-9.999 kg/kWh   Time...

Created on: 20 February 2014

FEATURES ● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.     SPECIFICATIONS       GENERAL     Maximum Rating between Poles 450V Category IV FUSES     Type HBC/HRC Rate of Rupture Slow Blow Current Rating 500mA    Voltage Rating 600V Quantity 2 VOLTMETER The Neon Voltage Scale Indication Neon lit when Voltage > or = 110V Neon lit when Voltage > or = 220V Neon...