Power analysers/Power meters

  1. physicspower is the rate at which energy is transferred, used, or transformed. The unit of power is the joule per second (J/s), known as thewatt (in honor of James Watt, the eighteenth-century developer of the steam engine). For example, the rate at which a light bulb transforms electrical energy into heat and light is measured in watts—the more wattage, the more power, or equivalently the more electrical energy is used per unit time.[1][2]

Energy transfer can be used to do work, so power is also the rate at which this work is performed. The same amount of work is done when carrying a load up a flight of stairs whether the person carrying it walks or runs, but more power is expended during the running because the work is done in a shorter amount of time. The output power of an electric motor is the product of the torque the motor generates and the angular velocity of its output shaft. The power expended to move a vehicle is the product of the traction force of the wheels and the velocity of the vehicle.

  • Filter
Created on: 19 May 2013

Allow you to download data without opening the switch or junction box cover. Any one can steal your power meter until you have this! >> Measures, Stores and Analyzes 144 Different Electical Parameters Including Volts, Amps, Watts, Volt-Amps (VA), Volt-Amps Reactive (VAR), Kilowatts (kW), Kilowatt Hours (kHW), Power Factor and Harmonics through 63rd

Created on: 19 May 2013

PRO0030 BASE UNIT POWER AND HARMONICS ANALYZER WITH 3 x 1000A CLAMPS Optional: PRO0041- 3 x 3000A Flexible Clamps Optional: PRO0038- 3 x 100A Clamps

Category: Power clamps
Created on: 19 May 2013

Analysis for Single Phase and Balanced 3 phase system True RMS Value (V and I) Active Power (K,KW,MW,GW) Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR) Power Factor (PF), Phase Angle( Φ ) Energy (WH,KWH,KVARH,PFH) Programmable PT(1 to 3000)Ratios Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W,KW,MW) with programmable Period Harmonic Analysis (V and I) to 50th Order Display of 25 Harmonics in one screen Optical Isolated RS-232C Interface Smart Datalogging to save Battery Datalogging of 32,64,128 or 256 points/cycles Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD 50000 Records with Programmable Interval (1 to 6000 seconds) Real-time Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Power for Long-term Monitoring Built -in Calendar Clock for Data Logging General Specification:         Conductor Size 55mm(approx.), 64*24mm(bus bar) Battery Type Two...