Data Logger Systems

  • Filter
Created on: 30 January 2014

MadgeTechs Vaccine Temperature Monitoring System (VTMS) is ideal for the continuous measurement and data logging of temperature sensitive vaccines or pharmaceuticals in refrigerators, freezers, and coolers. The system includes a NIST traceable RFTCTemp2000A data logger with thermocouple, Glycol bottle and a power supply. Additionally, the RFTCTemp2000A data logger in the VTMS system has a convenient LCD to ensure temperature parameters are met, in real time. The current reading, minimum, maximum and average statistics can all be obtained through the display. In the real-time chart recording mode the VTMS can alert the user, or other personnel, via e-mail or text message if the refrigerator has failed, or if the temperature is outside of the nominal range. This allows users to take immediate actions to ensure vaccines and pharmaceuticals in storage are not destroyed. To prevent false alarms, the RFTCTemp2000A is connected to a Glycol bottle which provides temperature buffered readings.

Created on: 30 January 2014

The AVS150 is a complete system used to perform autoclave validations. The AVS150 consists of a N.I.S.T. traceable HiTemp150 data logger, an IP68 extended range thermal shield, an IFC200 USB cable package and MadgeTechs Secure Software and IQ/OQ/PQ validation protocols, providing tools to users to assist with FDA 21 CFR Part 11 compliance. For larger size autoclaves or mapping projects, the AVS150-5, includes five HiTemp150s and five thermal shields. The HiTemp150 is completely submersible and can measure temperatures up to 150°C. The 2" rigid probe provides a fast response time and can record readings as fast as once per second. The HiTemp150 can be used in each autoclave cycle for verification and to provide data for validation. When used with the thermal shield the device can withstand up to 250°C (time dependent).   MadgeTech's Secure Software provides data in graphical and tabular form, and provides a summary and statistical report of the data. The software also features sterilization calculations to determine the F0 value. Furthermore the software allows for different user levels and logins, electronic signatures, an audit trail and a secure data file to stand up...

Created on: 30 January 2014

The AVS150-5 is a complete system used to perform autoclave validations. The AVS150-5 consists of five N.I.S.T. traceable HiTemp150 data loggers, five IP68 extended range thermal shields, an IFC200 USB cable package and MadgeTechs Secure Software providing tools to users to assist with FDA 21 CFR Part 11 compliance. For smaller size autoclaves or mapping projects, the AVS150, includes one HiTemp150 and one thermal shield.   The HiTemp150 is completely submersible and can measure temperatures up to 150°C. The 2" rigid probe provides a fast response time and can record readings as fast as once per second. The HiTemp150 can be used in each autoclave cycle for verification and to provide data for validation. When used with the thermal shield the device can withstand up to 250°C (time dependent).   MadgeTechs Secure Software provides data in graphical and tabular form, and provides a summary and statistical report of the data. The software also features sterilization calculations to determine the F0 value. Furthermore the software allows for different user levels and logins, electronic signatures, an audit trail and a secure data file to stand up to auditors.

Created on: 30 January 2014

MadgeTechs EGMS is specifically designed to measure and record the temperature and humidity of eggs during shipping, storage and incubation. The data logger thermally responds to an environment the same way a real egg does, simulating the temperature and humidity experience of the actual product. The EGMS comes with a humidity and temperature cap, and a temperature only cap. The temperature and humidity cap has vents to measure the humidity, where as the temperature only cap doesn't have any vents, and makes the product submersible. The EGMS can measure temperatures up to 60°C. It has a user replaceable battery, that typically lasts up to 1 year. The nonvolatile memory can hold up to 32,767 readings and will retain data even if the battery becomes discharged. MadgeTechs data logger software offers an easy way to analyze data. Data can be viewed in Celsius or Fahrenheit, and in graph, summary or data formats. For further analysis data can also be exported to Excel.

Created on: 30 January 2014

The ETR101A is a complete Exhaust Temperature Profiling Kit designed to profile the exhaust temperature of on-road vehicles and off-road equipment, including tractor trailers, buses, trucks over 14,000 lbs., waste water vehicles, and sweepers. The ETR101A kit comes assembled and includes a data logger, temperature sensor (thermocouple type K), weatherproof enclosure, USB data logger interface cable (IFC200), hex screwdriver and software. Setup is fast and easy. The data logger, which is contained within the water resistant enclosure, is mounted to the vehicle. Using the MadgeTech software, the logger is programmed to record for a set period, generally three to five days. Data is stored in the data logger, and is downloadable at any time via a pc or laptop computer. The complete temperature profile is then provided to the diesel particulate filter (DPF) manufacturer, aiding in the selection of the correct DPF for the exhaust system. Many DPF manufacturers, including Donaldson Corp., recommend the use of temperature profiling equipment, such as the MadgeTech ETR101A, to aid in the selection of the appropriate diesel particulate filter.

Created on: 30 January 2014

The HiTemp140-PT-TSK is a kit that includes a HiTemp140-PT data logger housed in a thermal shield. The combined features of the data loggers +/-0.1°C accuracy and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. The built in 24” RTD probe can be bent or spiraled in any direction, making it easy to log temperatures in hard to reach places. This rugged data logger system can be placed in and withstand temperatures from -200°C to 250°C, making it ideal for use in autoclave validation, monitoring food processing and dishwasher testing. Using the MadgeTech software, the data logger is fast and easy to setup. Remove the thermal shield and place the HiTemp140-PT into the IFC400 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Select Start to program the settings and start the data logger. Place the thermal shield around the HiTemp140-PT data logger and screw it back together. The device is ready to be deployed. The HiTemp140-PT-TSK data logger can be completely submerged and is built for applications that require extreme temperature...

Created on: 30 January 2014

The HiTemp140-TSK is a kit that includes a HiTemp140 data logger housed in a thermal shield. The combined features of the ±0.1°C accuracy of the HiTemp140 and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. This rugged system can be placed in and withstand temperatures from -200°C to 250°C, making it ideal for use in autoclave validation, monitoring food processing and dishwasher testing. Using the MadgeTech software, the data logger is fast and easy to setup. Remove the thermal shield and place the HiTemp140 into the IFC400 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Select Start to program the settings and start the data logger. Place the thermal shield around the HiTemp140 and screw it back together. The device is ready to be deployed. The HiTemp140-TSK can be completely submerged and is built for applications that require extreme temperature monitoring.

Created on: 30 January 2014

The HiTemp150-PT-TSK is a kit that includes a HiTemp150-PT temperature data logger enclosed in a thermal shield. This durable system can withstand temperatures up to 250°C. The thermal shield can be easily removed from the HiTemp150-PT, so it may be used as a standalone data logger also. Installing the data logger back into the thermal shield is simple, just open the enclosure, thread the probe through the end cap and fasten the thermal barrier together. The HiTemp150-PT-TSK is submersible and has a 24” flexible, stainless steel probe. The probe is durable and can be spiraled, bent or angled in any direction, making it easy to log temperatures within bottles, vials or other hard to reach places. The device can be started and stopped directly from a computer and the HiTemp150-PT-TSK’s compact design and ultra flexible probe allows it to fit almost anywhere. The MadgeTech software allows users to view the data in graph and summary views and print professional reports.