By Brands

Transmitters

  • Filter
Category: Transmitters
Created on: 21 February 2014

Measurement of differential pressure in the measuring range of 0 to 100 Pa Accuracy +/-1.2 percent of Measuring range: + intrinsic error of 0.3 Pa - valid for zeroing cycle of 60 sec/nominal temperature 22 ° C Freely scalable: +/-50 percent of measuring range final value and free scalability within the measuring range Piezoresistive sensor Automatic zero-point adjustment: via magnetic valve Protection class: IP65 only when the transmitter is wired and/or sealing plugs are in use Output type: 0 to 5V (3 or 4-wire) Measuring rate: 1/s Resolution: 12 bit Maximum load: 500 ohms Humidity (sensor): 0 to 90 percent rF Temperature (sensor): -5 to 50 ° C Storage temperature: -40 to 80 ° C

Category: Transmitters
Created on: 21 February 2014

Measurement of differential pressure, flow velocity and volume flow Automatic zero-point adjustment guarantees high, temperature-independent accuracy and long-term stability Display with multi-language operating menu and optical alarm display Ethernet, relay and analog outputs allow optimum integration into individual automation systems Self-monitoring of the transmitter and early warning function guarantee high system availability 4 relay outputs, limit value monitoring Cable entry NPT 1/2" Operating temperature: -5 to 50 ° C Storage temperature: -20 to 60 ° C Process temperature: -20 to 65 ° C Measures 162 mm length by 77 mm width by 122 mm height Piezoresistive sensor Measuring cycle: 1/sec Maximum load: 500 ohms Differential pressure: mbar/min/max Protection class: IP 65

Category: Transmitters
Created on: 21 February 2014

Automatic zero-point adjustment guarantees high, temperature-independent accuracy and long-term stability Low measurement range up to 10 Pa ensures highest precision at lowest pressures Flat housing allows flush surface integration in the cleanroom wall Display with multi-language operating menu and optical alarm display Differential pressure: scalable +/-50 percent of measuring range final value; freely scalable within measuring range Measuring cycle: 1/sec Resolution: 12 bit Maximum load: 500 ohms Front plate stainless steel, housing plastic material 3-line LCD with multi-language operating menu Operation temperature: -5 to 50° C Storage temperature: -20 to 60° C Process temperature: -20 to 65° C Measures 161 mm length, by 78 mm width, by 396 mm height Preparation for external humidity/temperature probe Testo 6610 Piezoresistive sensor

Category: Transmitters
Created on: 21 February 2014

Measurement of differential pressure; optional: humidity and temperature Automatic zero-point adjustment guarantees high, temperature-independent accuracy and long-term stability Low measurement range up to 10 Pa ensures highest precision at lowest pressures Flat housing allows flush surface integration in the cleanroom wall Display with multi-language operating menu and optical alarm display Preparation for external humidity/ temperature probe Testo 6610 Piezoresistive sensor 0.1 Pa Resolution 0.1 percent RH Humidity 0.01° C Temperature Protection class: IP 65 Operation temperature: -5 to 50° C Storage temperature: -20 to 60° C Process temperature: -20 to 65° C Measures 161 mm length, by 78 mm width, by 396 mm height

Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 0.25 to 75 Nm³/h Pipe diameter: DN 15 (for 1/2" pipes) Weight: 0.9 kg Max. display value norm volume flow: 90 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 0.75 to 225 Nm³/h Pipe diameter: DN 25 (for 1" pipes) Weight: 1.1 kg Max. display value norm volume flow: 270 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 1.3 to 410 Nm³/h Pipe diameter: DN 40 (for 1 1/2" pipes) Weight: 3.0 kg Max. display value norm volume flow: 492 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 2.3 to 700 Nm³/h Pipe diameter: DN 50 (for 2" pipes) Weight: 3.8 kg Max. display value norm volume flow: 840 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage